{"product_id":"gex-xy900-exproof-hmi-panel-atex-zone-2","title":"Exproof HMI Panel – ATEX Zone 2","description":"\u003cdiv data-gc-desc=\"stable-v3\" data-locale=\"en\" style=\"max-width:1400px;width:100%;margin:0 auto;padding:0;background:transparent;font-family:system-ui,-apple-system,'Segoe UI',Roboto,Helvetica,Arial,sans-serif\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#0f1419;border:1px solid #1e3a5f\" role=\"presentation\"\u003e\n\u003ctr\u003e\u003ctd style=\"height:4px;padding:0;background:#1d4ed8;font-size:0;line-height:0\"\u003e \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:32px 36px 36px;color:#e2e8f0\"\u003e\n\u003ch2 style=\"margin:0 0 12px;padding:0;font-size:24px;line-height:1.35;font-weight:700;color:#60a5fa;letter-spacing:-0.02em\"\u003eExproof HMI Panel – ATEX Zone 2\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 20px;padding:0\"\u003e\u003cspan style=\"display:inline-block;padding:6px 14px;border:1px solid #1d4ed8;background:#0b1220;color:#93c5fd;font-size:12px;font-weight:700;letter-spacing:0.06em\"\u003eSKU GEX-XY900\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0 0 12px;padding:0;font-size:15px;line-height:1.7;color:#e2e8f0\"\u003eExproof HMI Panel – ATEX Zone 2 is engineered for hazardous-area operator and access applications. Pricing is quote-based.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin-top:4px\" role=\"presentation\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:22px 0 10px;border:0;font-size:12px;font-weight:700;letter-spacing:0.08em;text-transform:uppercase;color:#60a5fa;border-bottom:2px solid #60a5fa\"\u003eHighlights\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:8px 0;border:0;color:#e2e8f0;font-size:14px;line-height:1.55\"\u003e\n\u003cspan style=\"display:inline-block;width:8px;height:8px;margin-right:10px;background:#60a5fa;vertical-align:middle\"\u003e\u003c\/span\u003eOperator HMI for hazardous-area control rooms and field stations\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:8px 0;border:0;color:#e2e8f0;font-size:14px;line-height:1.55\"\u003e\n\u003cspan style=\"display:inline-block;width:8px;height:8px;margin-right:10px;background:#60a5fa;vertical-align:middle\"\u003e\u003c\/span\u003eSuitable for process visualization and machine interface projects\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:8px 0;border:0;color:#e2e8f0;font-size:14px;line-height:1.55\"\u003e\n\u003cspan style=\"display:inline-block;width:8px;height:8px;margin-right:10px;background:#60a5fa;vertical-align:middle\"\u003e\u003c\/span\u003eIndustrial Ex enclosure ready for Zone-rated installations\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:8px 0;border:0;color:#e2e8f0;font-size:14px;line-height:1.55\"\u003e\n\u003cspan style=\"display:inline-block;width:8px;height:8px;margin-right:10px;background:#60a5fa;vertical-align:middle\"\u003e\u003c\/span\u003eCertification: ATEX Zone 2\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:8px 0;border:0;color:#e2e8f0;font-size:14px;line-height:1.55\"\u003e\n\u003cspan style=\"display:inline-block;width:8px;height:8px;margin-right:10px;background:#60a5fa;vertical-align:middle\"\u003e\u003c\/span\u003eProject-based pricing — request a quote\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:22px 0 10px;border:0;font-size:12px;font-weight:700;letter-spacing:0.08em;text-transform:uppercase;color:#60a5fa;border-bottom:2px solid #60a5fa\"\u003eTechnical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:0;border:0\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #1e293b\" role=\"presentation\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#0f1419;color:#94a3b8;width:34%;vertical-align:top;font-size:13px;font-weight:600\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#0f1419;color:#e2e8f0;vertical-align:top;font-size:14px;line-height:1.55\"\u003eGEX-XY900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#111827;color:#94a3b8;width:34%;vertical-align:top;font-size:13px;font-weight:600\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#111827;color:#e2e8f0;vertical-align:top;font-size:14px;line-height:1.55\"\u003eExproof HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#0f1419;color:#94a3b8;width:34%;vertical-align:top;font-size:13px;font-weight:600\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#0f1419;color:#e2e8f0;vertical-align:top;font-size:14px;line-height:1.55\"\u003eATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#111827;color:#94a3b8;width:34%;vertical-align:top;font-size:13px;font-weight:600\"\u003eHazardous area\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#111827;color:#e2e8f0;vertical-align:top;font-size:14px;line-height:1.55\"\u003eZone 2 class applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#0f1419;color:#94a3b8;width:34%;vertical-align:top;font-size:13px;font-weight:600\"\u003ePricing\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #1e293b;background:#0f1419;color:#e2e8f0;vertical-align:top;font-size:14px;line-height:1.55\"\u003eQuote only — project based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c!-- gc-iconex-source-specs:start --\u003e\u003csection class=\"gc-iconex-source-specs\"\u003e\u003ch2\u003eDetailed technical specifications from manufacturer datasheet\u003c\/h2\u003e\n\u003cp\u003eValues may vary by display size and order configuration. Confirm the exact model code, certification marking and interface options during quotation.\u003c\/p\u003e\n\u003cdiv class=\"gc-iconex-source-specs__table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eGEX-XY900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eExproof HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous area\u003c\/th\u003e\n\u003ctd\u003eZone 2 \/ Zone 21 \/ Zone 22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATEX\u003c\/th\u003e\n\u003ctd\u003eII 3G Ex nR IIC T6 Gc; II 2D Ex tb IIIC T80 C Db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIECEx\u003c\/th\u003e\n\u003ctd\u003eEx nR IIC T6 Gc; Ex tb IIIC T80 C Db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSizes\u003c\/th\u003e\n\u003ctd\u003e4.3\" \/ 7\" \/ 10.4\" \/ 12.1\" \/ 15\" \/ 17\" \/ 19\" \/ 15.6\" \/ 18.5\" \/ 21.5\" \/ 23.8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e480x272 to 1920x1080 (by model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrightness\u003c\/th\u003e\n\u003ctd\u003e300 cd\/m2 (high brightness optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouch\u003c\/th\u003e\n\u003ctd\u003eCapacitive, anti-static\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003e65,536 colors on compact models; 16.7 million colors on larger models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLCD lifespan\u003c\/th\u003e\n\u003ctd\u003e50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003e32-bit 800 MHz \/ 1 GHz RISC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMemory\u003c\/th\u003e\n\u003ctd\u003e256 MB Flash + 256 MB DDR3 or 4 GB Flash + 512 MB DDR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEthernet\u003c\/th\u003e\n\u003ctd\u003e1x 10\/100M RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial\u003c\/th\u003e\n\u003ctd\u003e2x RS232\/RS485\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB\u003c\/th\u003e\n\u003ctd\u003eUSB Host 1.1 + USB Device 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eXYFD2000 V4.1; USB or Ethernet program download; C-language macro support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput\u003c\/th\u003e\n\u003ctd\u003e24 VDC (21-28 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e4 W to 40 W nominal; 6 W to 85 W maximum by display size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable entries\u003c\/th\u003e\n\u003ctd\u003e3 to 8 x M20x1.5H by display size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 3 kg to 22 kg by display size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temp.\u003c\/th\u003e\n\u003ctd\u003eNT 0~50 C; LT\/WT options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage temp.\u003c\/th\u003e\n\u003ctd\u003e-40~70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e10~90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003c!-- gc-iconex-source-specs:end --\u003e","brand":"GeniusCore","offers":[{"title":"Default Title","offer_id":52972776882457,"sku":"GEX-XY900","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0957\/5088\/1561\/files\/01_c1128df7-33d3-48d8-b76f-9960ff84cddd.png?v=1786438507","url":"https:\/\/geniuscores.com\/products\/gex-xy900-exproof-hmi-panel-atex-zone-2","provider":"Genius Core Embedded Systems","version":"1.0","type":"link"}